GP-M45J-CX-03D 4N/L51-J,4N/L62-J Manual RD: Aug 2006 RL: 3D KH INFRA-RED POLE MOUNTED PATIO HEATER INSTALLATION / OWNER’S MANUAL SERIES 4N/L51-
GP-M45J-CX-03D 4N/L51-J,4N/L62-J Manual RD: Aug 2006 RL: 3D KH ASSEMBLY... CONTINUED Page 6 Insert the gas hose provided, into the top of the
GP-M45J-CX-03D 4N/L51-J,4N/L62-J Manual RD: Aug 2006 RL: 3D KH Page 7 ASSEMBLY... CONTINUED Assemble the reflector pieces to the centre piece
GP-M45J-CX-03D 4N/L51-J,4N/L62-J Manual RD: Aug 2006 RL: 3D KH Place a steel washer over each bolt on the burner top, before installing the Top
GP-M45J-CX-03D 4N/L51-J,4N/L62-J Manual RD: Aug 2006 RL: 3D KH If placing on concrete patio only: Drill 3 holes 1 3/4” deep using the 3/8” maso
GP-M45J-CX-03D 4N/L51-J,4N/L62-J Manual RD: Aug 2006 RL: 3D KH LEAK TEST: Now that the heater is assembled, for your safety you must perform a
GP-M45J-CX-03D 4N/L51-J,4N/L62-J Manual RD: Aug 2006 RL: 3D KH 7. A SAFE LOCATION FOR THE HEATER: Caution: When objects are left under
GP-M45J-CX-03D 4N/L51-J,4N/L62-J Manual RD: Aug 2006 RL: 3D KH 8. OPERATION AND LIGHTING INSTRUCTIONS: Page 10 ‘AAA’ Battery TO TURN ON: 1. F
GP-M45J-CX-03D 4N/L51-J,4N/L62-J Manual RD: Aug 2006 RL: 3D KH PROBLEM PROBABLE CAUSE SOLUTION Burner will not light Gas valve may be in OFF
GP-M45J-CX-03D 4N/L51-J,4N/L62-J Manual RD: Aug 2006 RL: 3D KH 9.3 SAFETY • Check periodically for leaks in the system, or immediately
GP-M45J-CX-03D 4N/L51-J,4N/L62-J Manual RD: Aug 2006 RL: 3D KH Some Authorities do not allow certain warranty exclusions or limitations on how l
GP-M45J-CX-03D 4N/L51-J,4N/L62-J Manual RD: Aug 2006 RL: 3D KH NOTICE: The Manufacturer. reserves the right to make changes to equipment and sp
GP-M45J-CX-03D 4N/L51-J,4N/L62-J Manual RD: Aug 2006 RL: 3D KH INFRA-RED POLE MOUNTED PATIO HEATER TABLE OF CONTENTS TOPIC
GP-M45J-CX-03D 4N/L51-J,4N/L62-J Manual RD: Aug 2006 RL: 3D KH 2. INSTALLATION REQUIREMENTS The Series 4N51/62, 4L51/4L62 and 44N/L5, 44N/L6
GP-M45J-CX-03D 4N/L51-J,4N/L62-J Manual RD: Aug 2006 RL: 3D KH GAS REQUIREMENTS AND LEAK TESTING: NATURAL GAS: NEVER CONNECT AN UNREGULA
GP-M45J-CX-03D 4N/L51-J,4N/L62-J Manual RD: Aug 2006 RL: 3D KH PROPANE: NEVER CONNECT AN UNREGULATED GAS SUPPLY TO THE HEATER. PRECAUTIO
GP-M45J-CX-03D 4N/L51-J,4N/L62-J Manual RD: Aug 2006 RL: 3D KH 4. MAIN COMPONENTS AND TOOLS REQUIRED FOR ASSEMBLY Tools Needed: (not supplie
GP-M45J-CX-03D 4N/L51-J,4N/L62-J Manual RD: Aug 2006 RL: 3D KH 5. MAIN COMPONENTS AND DIMENSIONS
GP-M45J-CX-03D 4N/L51-J,4N/L62-J Manual RD: Aug 2006 RL: 3D KH 6. ASSEMBLY INSTRUCTIONS Using screws, place L-shaped stabilizers to bottom bas