IM110810
RD: AUGUST 2011
RL; 1A
BA
InfraSave IEP-1524 Manual
INSTALLATION / OWNER’S MANUAL
Read all instructions before using this heater.
Read and understand all installation and maintenance
instructions thoroughly before installing or servicing this equipment.
Improper installation, operation, adjustment, alteration, service or mainte-
nance can result in the risk of fire and electrical shock, and may cause
property damage, injury or death.
SAFETY ALERT:
This heater must be serviced only by a qualified electrician. Failure to com-
ply could result in personal injury, death, fire and/or property damage.
Do not operate this heater unless it is properly installed.
Always disconnect the heater from the power source prior to servicing.
Do not store or use gasoline or other flammable vapours and liquids in
the vicinity of this or any other hot surface appliance.
Do not use or locate this model where it could fall into a bathtub or other
water container.
Do not cover or block any surface of this appliance.
Do not touch this appliance while in operation
- Allow to cool after use.
Read the IMPORTANT INFORMATION section of
this manual before using this appliance.
SAVE THESE INSTRUCTIONS
WARNING
INSTALLER: PRESENT THIS MANUAL TO THE END USER. Keep this manual in a secure place.
Record the following information for future reference if service is required:
Model #: IEP-1524
Serial #:
(located on heater rating label)
Model IEP-1524
Wall Fixed Electric Room Heater
INDOOR / OUTDOOR USE
Conforms to ANSI/UL 2021
Certified to CAN/CSA C22.2 No.46
3154365
Seitenansicht 0
1 2 3 4 5 6 ... 17 18

Inhaltsverzeichnis

Seite 1 - Model IEP-1524

IM110810 RD: AUGUST 2011 RL; 1A BA InfraSave IEP-1524 Manual INSTALLATION / OWNER’S MANUAL Read all instructions before using this heater. Read and

Seite 2

10 IM110810 RD: AUGUST 2011 RL; 1A BA InfraSave IEP-1524 Manual TABLE 2: MINIMUM REQUIRED CLEARANCES IEP 1524 Above ‘A’ Inches [cm] Floor ‘F’ Inches [

Seite 3 - Table of Contents

11 IM110810 RD: AUGUST 2011 RL; 1A BA InfraSave IEP-1524 Manual 6. The Mounting Bracket fastens to the structure using field supplied bolts or lag sc

Seite 4 - 1. IMPORTANT INSTRUCTIONS

12 IM110810 RD: AUGUST 2011 RL; 1A BA InfraSave IEP-1524 Manual 6. OPERATING INSTRUCTIONS 5. ELECTRICAL CONNECTION Connect heater to a 115 - 120 Vac,

Seite 5 - “SAVE THESE INSTRUCTIONS”

13 IM110810 RD: AUGUST 2011 RL; 1A BA InfraSave IEP-1524 Manual 7. MAINTENANCE INSTRUCTIONS WARNING Heater service should only be performed by a qual

Seite 6

14 IM110810 RD: AUGUST 2011 RL; 1A BA InfraSave IEP-1524 Manual 9. HEATER PARTS 1 2 3 4 5 6 7 8 9 12 13 11 1. Heater Body - cast aluminum 2. Polishe

Seite 7

15 IM110810 RD: AUGUST 2011 RL; 1A BA InfraSave IEP-1524 Manual ALWAYS WEAR COTTON OR OTHER FABRIC GLOVES WHEN REPLACING HEAT LAMP. DO NOT TOUCH THE

Seite 8

16 IM110810 RD: AUGUST 2011 RL; 1A BA InfraSave IEP-1524 Manual Heat Lamp Replacement: … continued Step 4 Remove 2 Phillips screws that fasten the co

Seite 9 - BEFORE PROCEEDING

17 IM110810 RD: AUGUST 2011 RL; 1A BA InfraSave IEP-1524 Manual Heat Lamp Replacement: … continued Step 9 Remove end plate from heater: 6 Phillips sc

Seite 10 - IEP 1524

18 IM110810 RD: AUGUST 2011 RL; 1A BA InfraSave IEP-1524 Manual InfraSave IEP SERIES HEATERS - LIMITED WARRANTY CERTIFICATE The Manufacturer warrants

Seite 11 - HEATER BRACKET

2 IM110810 RD: AUGUST 2011 RL; 1A BA InfraSave IEP-1524 Manual NOTICE: This contents of this manual are current for this product at the date of manuf

Seite 12 - 5. ELECTRICAL CONNECTION

3 IM110810 RD: AUGUST 2011 RL; 1A BA InfraSave IEP-1524 Manual IEP 1524 Wall Fixed Electric Room Heater For INDOOR / OUTDOOR USE Table of Contents 1

Seite 13 - 8. CLEANING

4 IM110810 RD: AUGUST 2011 RL; 1A BA InfraSave IEP-1524 Manual 1. IMPORTANT INSTRUCTIONS When using electrical appliances, basic precautions should

Seite 14 - FIGURE 5:

5 IM110810 RD: AUGUST 2011 RL; 1A BA InfraSave IEP-1524 Manual 14. To prevent a possible fire, do not block air intakes or exhaust in any manner. Do

Seite 15 - Step 3

6 IM110810 RD: AUGUST 2011 RL; 1A BA InfraSave IEP-1524 Manual 2. HEATER DIMENSIONS, WIRING, SPECIFICATIONS - IEP 1524

Seite 16

7 IM110810 RD: AUGUST 2011 RL; 1A BA InfraSave IEP-1524 Manual 3. PROJECT DESIGN CONSIDERATIONS & GUIDELINES: NOTE: Also refer to Section 4. Inst

Seite 17

8 IM110810 RD: AUGUST 2011 RL; 1A BA InfraSave IEP-1524 Manual ft [m] ft [m] ft [m] ft [m]ft2 [m2] watts / ft2Min. 7 [2.1] 8.8 [2.7] 8.5 [2.6] 16 [4.9

Seite 18 - InfraSave IEP-1524 Manual

9 IM110810 RD: AUGUST 2011 RL; 1A BA InfraSave IEP-1524 Manual 4. INSTALLATION INSTRUCTIONS General: READ ALL INSTRUCTIONS AND PLAN THE INSTALLATION